  • Centrifugal Pump Selection Guide - Goulds Pumps

    pumps. Heavy duty slurry pumps like the XHD, SRL and 5500 are specially designed for flue gas scrubbers and ash handling services. The Rheinhütte pump model GVSO is ideally suited for solar power systems, with an immersion depth of up to 17.5 metres and for temperatures up to 600°C. Plastic pumps are widely used for waste plant incinerations

  • Introduction to Open Loop Geothermal Geothermal Pros and

    Jun 05, 2012· How is Open Loop Different from Closed Loop Geothermal? From inside your home or office, you wont know the difference. You dont HAVE to have any bulky extra equipment, and you can use the exact same heat pump. The one piece of equipment we do recommend is a small water filter, depending on your water source.

  • A process plant drains systems - Project Controls

    Nov 13, 2012· A plant will have numerous such small bleed-off points. Due to the small inventory of process fluids contained, the drain valves will be open directly to atmosphere. These drains are, for this reason, called "Open Drain" (OD). They will be collected either by mobile equipment or dumped in the area water drainage. Oily drains:

  • Overhauling Centrifugal Pumps - Procedure to Dismantle and

    Nov 27, 2009· 3. Close suction and discharge valves, chain and lock hand wheels. 4. Open pump suction and discharge pipe drain valves to bilge and when water ceases to flow; crack open the pipes / pump flange joints carefully to ensure that pump has drained off and is safe for opening. 5.

  • Isolation of Mechanical and Electrical Equipment

    Steam Turbine Driven Pump The procedure to isolate the equipment shown in Fig. 1 is as follows: - Close the high pressure steam supply valve. - Close the turbine (lp steam) exhaust valve. - Open the turbine casing drain. - Close the pump discharge valve. - Close the pump suction valve. - Close the minimum flow line isolating valve.

  • Hydraulic machinery - Wikipedia

    Hydraulic machines use liquid fluid power to perform work. Heavy construction vehicles are a common example. In this type of machine, hydraulic fluid is pumped to various hydraulic motors and hydraulic cylinders throughout the machine and becomes pressurized according to the resistance present. The fluid is controlled directly or automatically by control valves and distributed through hoses

  • Graco Equipment for Composite Materials Graco

    Our equipment covers a wide range of open, closed and manual fabrication processes. Composite Bonding Equipment Graco offers a complete line of meter mix and dispense equipment for industrial bonding and assembly applications involving two-component composite materials.

  • Main Parts of a Centrifugal Pump Description of

    Main Parts of a Centrifugal Pump. Each centrifugal pump is made of hundreds of parts. There are a few components that virtually every centrifugal pump has in common. These components can be subdivided into the wet end and the mechanical end.. The wet end of the pump includes those parts that determine the hydraulic performance of pump.The two primary wet ends are the impeller and casing.

  • The Steam and Condensate Loop Spirax Sarco

    Mechanical (steam powered) pumps are used for this purpose. These, or electric powered pumps, are used to lift the condensate back to the boiler feedtank. A mechanical pump, see Figure 1.3.7, is shown draining an item of plant. As can be seen, the steam and condensate system represents a

  • Shut down management - Plant Maintenance

    Manage site/plant access for resources, vehicles, equipment, and tools. Manage indirect hire, contractor, subcontractor, and service personnel at the site/plant. An effective method is developed for shut down management of coal handling plant of thermal power stations. 3. Maintenance Shutdown Management: -

  • Monitoring and Treatment of Closed-Loop Cooling Water Systems

    Mar 01, 2016· Other closed-loop cooling systems can include chilled water systems for air chillers used at the air inlet to the gas turbines at a combined cycle power plant and the chemistry sample panel.

  • Standard Operating Procedure: Pumps

    Oct 31, 2016· pump repair should be considered and close attention should be given to pump maintenance and usage for future use. 3. When all oil is drained, the pump should be placed in a level position, the drain valve should be closed, flushing oil should be added through the exhaust port until the max oil level is achieved,

  • Ancillary Extraction Equipment Precision Extraction

    You depend on your equipments uptime to make money and we understand reliability and speed matter. All of our ancillary equipment comes with a minimum 1-year warranty. In the event of a warrantable issue, next-day air shipping is standard.

  • Fundamentals Of Pumps

    CENTRIFUGAL PUMPS DOE-HDBK-1018/1-93 Pumps. Impellers can be open, semi-open, or enclosed. The open impeller consists only of blades attached to a hub. The semi-open impeller is constructed with a circular plate (the web) attached to one side of the blades. The enclosed impeller has circular plates attached to both sides of the blades.

  • Motor Operated Valve - EnggCyclopedia

    Open/close valves - used to automate manual open close valves Examples include, pump discharge / suction valves, boiler feed water isolation valves, drum vent valves, product line valves etc. Inching valves - used were some degree of control. Example a gradual opening and closing is required, applications include, reflux lines, boiler start up

  • Basics of Trips, Interlocks, Permissives & Sequences

    Resetting the Trip will not cause the pump to automatically re-start, however it may be re-started by an operator action or a control system command e.g. part of a sequence. The resetting of Trips is a controlled procedure which will only be possible if the operator is

  • Wastewater Grinders Inline Sewage Grinders Macerators

    With our innovative hollow spherical rotor SUPER SHREDDER® and our TASKMASTER® twin-shaft grinders, we have the ability to combat plugging problems associated with sanitary wipes. Franklin Miller will have the right processor for your needs. Our grinders improve the reliability, life and performance of your pumps, centrifuges, digestors and other process equipment.

  • Close Coupled Vertical Turbine Pumps - National Pump Company

    Every piece of rotating machinery (motor, pump, etc.) has a natural frequency or vibration of operation. As the discharge head of the pump supports the motor, it is the responsibility of the pump manufacturer to design the discharge head to withstand the natural frequencies of the motor through its operating speed range (say 45 60 HZ, or 1350 1800 rpm).

  • Closed Loop VS Open Loop Hydraulic Systems - CrossCo

    Mar 21, 2017· A piston pump is injecting fluid one piston at a time into the loop and will have inherently better and more consistent control. With mobile machinery, the best answer is often a combination of open and closed loop circuits running at the same time to perform all of the desired functions.

  • Pumped-Storage Hydropower Department of Energy

    Pumped-storage currently accounts for 95% of all utility-scale energy storage in the United States. The U.S. Department of Energy's (DOE's) Water Power Technologies Office (WPTO) invests in innovative pumped-storage technologies and research to understand and value the potential benefits of existing and prospective advanced pumped-storage facilities.

  • Process Engineering Pump start-ups Chemical Processing

    Jan 09, 2006· Prime the pump. To do this with a flooded suction, the suction valves are opened and the liquid is allowed to flow into the pump. It may also be necessary to open an air release valve at the highest point in the pump casing to ensure that all the air/vapor is bled

  • Closed Drain System For The Process Plant - Industrial

    Oct 15, 2012· Closed Drain System For The Process Plant - posted in Industrial Professionals: Dears, I need your help for understanding the Closed Drain System. Below is the matter As per Engineering Standards Closed Drain System Drum shall be installed either at grade or below grade. However, in one of our unit the elevation of CDS Drum (Z99-D-0018) is 5000 mm above ground.

  • Used Plant Machinery & Equipment For Sale Auto Trader Plant

    Open / close Menu. Sell. Main site menu . Sign up or sign in . Sell your plant machinery today. Create your advert in minutes. Sell my plant machinery Sell here . Plant services & products. Tracks, Attachments & Tyres. Visit our partners for a comprehensive range of spare plant equipment parts, including rubber tracks and undercarriage parts.

  • What You Should Do Before a Plant Closure

    Pumps, Engines, Compressors and Machinery To minimize internal corrosion, close off all vents and openings, and completely fill the casing with the manufacturers recommended lubricant. Alternatively, add a volatile corrosion inhibitor in the correct proportion to the lubricating oil.

  • Surge Control in Pumping Stations Pumps & Systems

    Dec 17, 2011· The pump control valve can close rapidly during power outages or pump trips to protect the pump. However, when rapid closure is required, additional surge equipment will be needed, as explained in the following section. First, though, the selection criteria pertaining to pump control valves will be presented.

  • Ball Mill Operation -Grinding Circuit Startup & Shutdown

    Feb 01, 2016· Check the plug valves in the mill discharge distribution box for correct open or closed position depending on which pump-box compartment is to be used. Check that the plant air shut-off valves are open to the cyclone apex valves and to the distribution box plug valves.. Check that the cyclone feed pump-box and pump suctions are not sanded.

  • Boiler Feed Water Pump Working Principle and Operation

    Jul 18, 2018· (2) The pump and pipings are fully primed and vented. (3) Suction valve fully open (4) Discharge valve closed (5) Minimum flow shut-off valve open (6) Cooling water system running (7) Oil pump in operation. (8) Differential temperature between top and bottom on barrel within 20°C. Pumps Start and Check: (1) Oil supply pressure (2) Pump suction

  • Open And Close Equipment - Rosenberg, TX

    Open And Close Equipment geared to offer the oil industry a wide variety of both standard and custom units which will fit your needs. Open And Close Equipment - Rosenberg, TX 2808 Hartledge Rd.

  • Hydraulic Institute

    The Hydraulic Institute (HI) is the global authority on pumps and pumping systems.HI is a pump association of positive displacement and rotodynamic, centrifugal pump manufacturers and suppliers whose mission is to be a value-adding resource to member companies, engineering consulting firms, and pump users worldwide.

  • PUMP MANUFACTURERS

    Mar 05, 2018· PUMP MANUFACTURERS. Pump Manufacturers is a website that lists all types of pump manufacturers from around the world. You can go through the site and you will find companies either manufacturing or supplying different types of pumps for various applications.

  • Useful information on External Gear Pumps

    External gear pumps can also be used in hydraulic power applications, typically in vehicles, lifting machinery and mobile plant equipment. Driving a gear pump in reverse, using oil pumped from elsewhere in a system (normally by a tandem pump in the engine), creates a motor.

  • Vertical Turbine Pumps - Deep Well - National Pump Company

    Every piece of rotating machinery (motor, pump, etc.) has a natural frequency or vibration of operation. As the discharge head of the pump supports the motor, it is the responsibility of the pump manufacturer to design the discharge head to withstand the natural frequencies of the motor through its operating speed range (say 45 60 HZ, or 1350 1800 rpm).

  • The safe isolation of plant and equipment (HSG253)

    The safe isolation of plant and equipment Page 3 of 81 Health and Safety Executive Contents Foreword 4 Introduction 5 Scope and target audience 5 Legal considerations 6 Risk reduction and ALARP 6 Overview of isolation hazards 7 Management of isolations 7 Basic principles 7 Design 8 Human factors 10 Roles and responsibilities 12 Training and competence 14 Monitoring, audit and review 15

  • CENTRIFUGAL PUMP SELECTION, SIZING, AND

    CENTRIFUGAL PUMP SELECTION, SIZING, AND INTERPRETATION OF PERFORMANCE CURVES 4.0 PUMP CLASSES Pumps may be classified in two general types, dynamic and positive displacement. Positive displacement pumps are those in which energy is imparted to the liquid in a fixed displacement volume, such as a casing or a cylinder, by the rotary motion of gears,

  • Wastewater Technology Fact Sheet: In-Plant Pump Stations

    In-Plant Pump Stations DESCRIPTION The terrain of the treatment plant site and the influent sanitary sewer depth govern the need for and location of in-plant pumping facilities. In-plant pump stations are facilities that consist of pumps and service equipment designed to pump flows from lower to higher elevations to allow continuous

  • PLANT START-UP AND SHUT-DOWN SEQUENCE

    PLANT START-UP AND SHUT-DOWN SEQUENCE ENGSOFT Lab Gas Performance Heater Permissive Signal pick up. Start up with feedwater higher than 48 oC [120 oF], the fuel gas temperature control valve shall be closed before gas turbine startup. Equipment/System Condition Tag No. Remarks Feedwater supply isolation valve Valve open

  • How does a concrete batch plant work Operation of

    May 25, 2017· Before we understand the working or operation of a concrete batch plant.It is important to understand the basic components and structure of a batching plant.We have mobile concrete plants installations in Philippiness city like: Bulacan, Cavite and Pampanga.It is a machine that combines various ingredients like aggregates, sand, water, cement and additives.These components are first

  • Back to Basics Pump Sizing - AIChE

    In a positive-displacement (PD) pump, a discrete amount of fluid is trapped, forced through the pump, and discharged. A gear pump is an example of a PD pump (Figure 2). This pumping principle produces a pulsating flow, rather than a smooth flow. Its output flow tends to vary little with respect to the pressure at the pump outlet, because the moving

  • Cooling Systems IPIECA

    Fans and pumps Fans, blowers, and pumps may be idled or slowed during times of favorable weather conditions or low plant load to reduce energy consumption Variable Speed Drives (VSDs; also called Adjustable Speed Drives, or ASDs) are commonly used on fan, blower and pump motors because they greatly improve cooling system energy efficiency

  • Piping and instrumentation diagram - Wikipedia

    A piping and instrumentation diagram (P&ID) is a detailed diagram in the process industry which shows the piping and process equipment together with the instrumentation and control devices.. Superordinate to the P&ID is the process flow diagram (PFD) which indicates the more general flow of plant processes and the relationship between major equipment of a plant facility.

Online Consultation Contact Details QR Code

Service Hotline

+86-13585569799

Scan to contact us